My WATTSTemp seems work correctly but the output is not
activated even if the temperature in the room is under the
Sensor logo
My WATTSTemp seems work correctly but the heating doesn‟t
Output
My WATTSTemp seems work correctly but the temperature
in the room was never in accordance with the program.
Program
8

Divers

Corresponding value for the external sensor NTC 10k at 25°C
To be checked with an ohmmeter, only when the sensor is
disconnected.
-10°C / -14°F
0°C / 32°F
10°C / 50°F
20°C / 68°F
25°C / 77°F
30°C / 86°F
40°C / 104°F
setting.
&
The upper floor limitation is activated,
the heat is switch off to prevent
damage because the floor temperature
is above the upper floor limitation.
No message or logo displayed.
Your thermostat use a "PWM"
regulation, it can switch off the heat (by
cycle) even if the temperature is under
the setting.
work correctly
- Check the connections.
- Check the power supply of the
heating element.
- Contact your installer.
- Check the Clock.
-The difference between Comfort &
Reduced temperature is too high?
- The step in the program is too
short?
- Contact your installer, to check &
adjust the regulation parameters with
your heating system.
~55k ohms
~32k ohms
~19k ohms
~12,5k ohms
10k ohms
~8k ohms
~5,3k ohms
26
The logos blinks