AHT Cooling Systems GmbH | en
The appliance is equipped with Plastic panel.
NOTICE
Material and property damage due to missing
parts on the appliance.
§ Operating personnel must check the presence of
the Plastic panel.
Presence of the plastic screen is a prerequisite for cor-
rect functioning of the appliance.
Fig. 2: Plastic screen (1)
The appliance is equipped with stickers.
– Power rating plate [see } Chapter 3.2.1]
– Loading specification [see } Chapter 10.1]
– Symbol
The stickers are located at the top right inside the ap-
pliance.
Inspection tasks
– Presence of the stickers
– Presence of the plastic screen
– Function of the self-closing mechanism on the
doors
Responsibility
– Operating personnel
Frequency
See Maintenance [see } Chapter 11]
If any parts are missing or in the event of a malfunc-
tion, contact the maintenance service immediately
[see } Chapter 12.5].
4.1
Automatic defrosting
The appliance features automatic defrosting.
The frequency, duration, and time of defrosting are
preset.
Defrost time
– Up to 60 min
Display
During automatic defrosting, the following display
screen and symbols appear on the display
[see } Chapter 5].
Display
428175_1_0121
The water produced with defrosting is collected in a
collection tray (base tray with drain
[see } Chapter 11.1.1]) and drained off via a defrosting
water drain [see } Chapter 8].
1
During the defrosting process, an increase in the tem-
perature can occur on the internal temperature dis-
play.
4.2
The appliance lighting can, for example, be coupled to
the market lighting.
Control by external day/night signal.
Technical data [see } Chapter 3.2]
Day mode function
If the day mode is switched on, the appliance lighting
is automatically on.
Night mode function
If the day mode is switched off, the appliance lighting
is automatically off.
5
5.1
Internal appliance temperature display (air
temperature)
The temperature display is located at top left of the
goods area.
Fig. 3: Interior temperature display
More information [see } Chapter 3.4]
Check of internal temperature
Responsibility
Symbol
– Operating personnel
Frequency
See Maintenance [see } Chapter 11]
Control and display elements | 5
CAUTION
Leakage of condensation water.
Slipping hazard.
§ Check for puddles in front of and under
the appliance.
§ Promptly remove leaking condensation
water.
§ Contact the maintenance service immedi-
ately [see } Chapter 12.5].
Automatic appliance lighting
Control and display
elements
Temperature display
41 / 220