Samsung DVE45R6300 Serie Manuel D'utilisation page 27

Masquer les pouces Voir aussi pour DVE45R6300 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

STEP 3 Connect the electrical wiring (for electric models)
Before connecting the electrical wiring, make sure you have read the "Electrical
requirements" section on page 21.
3-wire system
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E. 3/4" (1.9 cm) UL-listed strain relief
Untitled-1 27
1. Loosen or remove the center terminal
block.
2. Connect the neutral wire (white or
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
3. Connect the other wires to outer
terminal block screws. Tighten the
screws.
4. Tighten the strain relief screws.
5. Insert the terminal block cover into the
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
• To convert from the 4-wire system
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
• Ring-type terminals are recommended.
If using strap terminals, make sure they
are tightened.
English 27
2019-09-16
4:03:44

Publicité

Table des Matières
loading

Table des Matières