Belkin Pureav Battery Backup Features And Functions - Belkin PureAV AP30800fc10-BLK Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Belkin PureAV Battery Backup Features
and Functions
On/Off/Test Switch
Indicator
BATTERY ON
(Green LED)
OVERLOAD
(Yellow LED)
REPLACE
BATTERY
(Red LED)
SITE WIRING
FAULT
(Red LED)
LOAD
(Yellow LED)
BATTERY
(Green LED)
3
LED Indicator
Condition
The Belkin PureAV Battery Backup is on
battery-backup mode and an intermittent
Solid
audible alarm is on. The Battery Backup will
Green
begin shutdown procedure.
Battery is low. The Belkin PureAV Battery
Backup will start shutdown. The buzzer sounds
Flashing
an audible alarm.
Green
The Belkin PureAV Battery Backup shut down
due to an overload or short-circuit condition.
Solid
Yellow
Battery output is drawing more power than the
Battery Backup can provide.
Flashing
Yellow
Battery is weak or bad; the battery needs
to be replaced.
Solid
Red
There is either no ground circuit or a
reversed polarity in the building wiring.
Solid
Red
This display shows the Belkin PureAV Battery
Backup output load percentage level of 17%,
Solid
33%, 50%, 67%, and 85%.
Yellow
This display shows the battery capacity
percentage level of 20%, 40%, 60%, 80%, and
Solid
100%.
Green
Site Wiring Fault
Battery On
Replace Battery
Overload
Battery
Load
Meaning

Publicité

Chapitres

Table des Matières
loading

Table des Matières