Victron energy VGR Mode D'emploi page 12

Le contrôle à distance mondial
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.3 Log period
When the GPRS Internet connection is enabled, the VGR will periodically log data to the Internet.
By default logs are sent every 15 minutes, as well as whenever an alarm occurs or clears. Under
normal circumstances, this will require less than 1.5MB of data transfer per month.
To increase the amount of information available on the web site, the time between logs can be
reduced. This will however increase the data usage, which could lead to higher charges by your
network provider.
The time between logs can alternatively be increased in order to reduce data usage.
Note: The log period is specified in minutes.
Note: Periodic logging can be disabled by setting the log period to 0.
4.3.1. Examples
Set the log period to 5 minutes:
log period 5
Disable periodic logging:
log period 0
Note: Even with periodic logging disabled, data will still be logged for any alarms that occur. To
disable logging completely, the GPRS Internet connection must be switched off (gprs off).
8

Publicité

Table des Matières
loading

Table des Matières