Description of the product, operating elements
2
1
3
4
1 Retaining clips for ceiling installation
2 Strain relief for connection cables
3 Transparent cover, removable
4 Spring clips for mains voltage and consumer
5 Control dial "TIME" for adjustment of the switch time
6 Control dial "LUX" for adjustment of the brightness-switch threshold
Installation
Please pay attention to the information in the chapter "Preparations for Installation"!
• Remove the transparent cover (3), by carefully pressing it at the left and right sides, so the clips
will loosen from the casing of the motion switch.
• Unscrew both screws of the strain relief (2) and remove them.
• Connect the mains cable and the cable to the consumer with the spring clips (4). The terminal
assignment is indicated for the spring clips:
L
= Phase (right side of the picture "L")
N
= Neutral wire
A
= Switch output (right side of the picture "A")
Please note the accompanying switch example.
Make sure that the cables are not jammed or
damaged.
• Fix the strain relief via the cable.
• Place the transparent cover back in place, note the correct polarity. Both cover clips need to
lock in the casing of the motion switch.
The operation of the motion switch is only allowed with a correct placed transparent
cover!
• Set both control dials "TIME" and "LUX", notice the chapter "Function and adjustment of the
motion switch" further down in these operating instructions,
• Bend both retaining clips together and guide them through the ceiling section. Push the motion
switch far enough in the prepared ceiling/wall section, until both retaining clips well fixed.
Function and adjustment of the motion switch
The PIR-motion detector integrated motion switch responds to temperature changes within the
detection range, e.g. if a person, an animal or a car enters the detection area.
After switching on the mains voltage, it takes about 30-60 seconds until the PIR-motion detector
has adjusted to the background temperature and is able to recognise changes in temperature
within the detection area..
The detection range can be restricted by covering the plastic lens of the motion detector e.g. with
a strip of non-transparent adhesive tape.
• Setting the on-time (control dial "TIME")
Using this control, you can set the duration for the on-time. Turning the control knob counter-
clockwise shortens the on-time, turning it clockwise lengthens it.
• Setting the brightness adjustment (control dial "LUX")
This control serves for setting the switch threshold, from which the ambient brightness of the
motion switch will activate.
When turning it left the motion switch will only activate with complete darkness, turning it to the
right will already activate it with a more brighter environment.
1
5
L
N
Maintenance and care
The motion switch is maintenance free, this is why you should never open it or take it apart (aside
from the jobs described in this operating instruction).
Maintenance or repairs may only be performed by qualified personnel.
Clean the diffusing panel of the motion switch occasionally from dust or sediments, by only using
a dry, clean and soft cloth.
Disposal
Dispose of an unserviceable product in line with the relevant statutory regulations.
6

Technical data

Operating voltage ................................220 - 240 V/CA, 50 Hz
Input power ..........................................max. 0.45 W
Switching power ..................................1200 W (resistive load)
Consumers with mainly ohmic load are e.g. light bulbs, heaters etc.
Consumers with inductive load are e.g. engines, control gears, conventional trans-
formers, energy saving light sources etc.
Protection class ....................................II
Mounting location ................................Wall or ceiling installation, only in dry, closed interiors.
Detection angle ....................................360°
PIR range ............................................Max. 6 m (at ambient temperature < 24 °C)
Installation height..................................2.2 to 4 m
Operation time ......................................Min. 10 ±3 seconds to max. 15 ±2 minutes
Ambient brightness ..............................Adjustable, < 3 Lux to 2000 Lux
Ambient temperature ............................-20 to +40 °C
Ambient air humidity ............................max. 93% relative humidity, not condensing
A
Dimensions (Ø x D) ..............................76 x 75 mm
Installation section-Ø ............................63 mm
Installation depth ..................................60 mm
Weight ..................................................approx. 97 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
(www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or
the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited. This publication represent the technical status at the time of
printing.
© Copyright 2014 by Conrad Electronic SE.
..................................................
300 W (inductive load)