Never use the machine with a damaged cable. Do not
touch the damaged cable and pull the mains plug when
the cable is damaged while working. Damaged cables
increase the risk of an electric shock.
Keep hands away from the cutting area while
the machine is running. Danger of injury when
coming into contact with the cutting disc.
Wear ear protectors. Exposure to noise can
cause hearing loss.
Wear safety goggles.
Wear a dust respirator.
Wear protective gloves.
Instructions for use
Placement Tool
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious
injury.
Assembly
Avoid unintentional starting of the machine.
During assembly and for all work on the
machine, the power plug must not be
connected to the mains supply.
Carefully remove all parts included in the delivery from
their packaging. Remove all packaging material from the
machine and the accessories provided.
Before starting the operation of the machine for the first
time, check if all parts listed below have been supplied:
– Cut-off grinder with mounted cutting disc
– Ring spanner
Make sure that the power tool has no defect
whatsoever. Before each use of the power tool, the
protective devices or any slightly damaged parts
must be carefully checked to ensure that they work
perfectly and in accordance with the specific intended
use. Check that the moving parts work perfectly and that
they do not lock and make sure that there are no
damaged components. All parts must be assembled
correctly and in accordance with all the conditions
envisaged to guarantee perfect machine operation.
In caso di dispositivi di protezione e parti danneggiati si
deve provvedere a far eseguire una riparazione oppure
una sostituzione degli stessi rivolgendosi ad un'officina
specializzata munita di debita autorizzazione.
Stationary or flexible mounting
In order to ensure safe handling, before use, the tool must
be mounted on a flat and resistant work surface (e.g.
workbench).
ENGLISH
19
Stationary mounting
- Using a suitable screw fitting, fix the power tool on the
work surface. For this purpose, holes 11 are provided.
Flexible mounting (not recommended!)
In the exceptional case that it should not be possible to
firmly bench-mount the power tool, you can provisionally
place the legs of base plate on a suitable surface (e. g.
a workbench, level floor, etc.) without bolting the machine
down.
Illustrated description
1 Service key.
2 Spindle lock.
3 Lower stop adjustment.
4 Stop the fixing screw.
5 ON / OFFswitch
6 Spindle lock
7 fixed mounting holes.
8 Pin to collect the head.
Operating instructions
Placement and testing
Observe correct mains voltage! The voltage of the
power source must agree with the voltage specified
on the nameplate of the machine. Power tools marked
with 230 V can also be operated with 220 V.
Check the cutting disc 6 before using. The cutting
disc must be properly mounted and must rotate
freely. Carry out a 30 second (min.) test run with no
load. Do not use damaged, out-of-centre or vibrating
cutting discs.
Damaged cutting discs 6 can burst and cause injuries.
Dusts from materials such lead-containing coatings,
minerals and metal can be harmful to one's health.
Contact with or inhaling the dusts can trigger allergic
reactions to the operator or bystanders and/or lead to
respiratory infections.
Certain metal dusts are considered hazardous, especially
in conjunction with alloys such as zinc, aluminium or
chromium. Materials containing asbestos may only be
worked by specialists.
– Provide for good ventilation of the working place.
– It is recommended to wear a P2 filter-class respirator.
Observe the relevant regulations in your country for the
materials to be worked.
The cutting wheel can get stuck in the recess of the bed
due to dust, shavings or through broken pieces of the
workpiece.
– Switch the machine off and pull the mains plug from the
socket outlet.
– Wait until the cutting disc 6 has come to a complete
stop.
19