Télécharger Imprimer la page

Accessing Internal Components; Storing Machine In Freezing Temperatures; Recommended Stock Items - Nobles QUICK CLEAN 1500 Manuel Opérateur Et Piéces

Publicité

Les langues disponibles

Les langues disponibles

FOR SAFETY: When servicing machine, all repairs
must be performed by a qualified service person.

ACCESSING INTERNAL COMPONENTS

The machine is designed to hinge open to access
internal components. Follow steps below to open
machine.
WARNING: Electrical Hazard. Unplug Power
Cord Before Servicing Machine.
FOR SAFETY: When servicing machine, all repairs
must be performed by a qualified service person.
1. Empty recovery and solution tanks before opening
machine.
2. Unplug power cord from wall outlet.
3. Unlatch two latches at front of machine and
carefully hinge machine open (Figure 46).
FIG. 46
4. When closing machine, make sure hoses are not
pinched or kinked.
STORING MACHINE
1. Before storing machine, perform the
recommended maintenance procedures (See
MACHINE MAINTENANCE).
2. Store machine in a dry area in the upright position.
3. Open recovery tank cover to promote air
circulation.
WARNING: Electrical Shock Hazard. Do Not
Use Outdoors. Do Not Expose To Rain. Store
Indoors.
ATTENTION: DO NOT ALLOW MACHINE TO
FREEZE WITH WATER IN PUMP SYSTEM.
Quick Clean 1500 (06- -06)
STORING MACHINE IN FREEZING
TEMPERATURES
1. Drain and rinse tanks thoroughly.
2. Pour 32 oz / 1 L of undiluted standard antifreeze
into solution tank.
3. Spraying into a bucket, operate spray gun for 30
seconds at low pressure.
4. Allow antifreeze to remain in system.

RECOMMENDED STOCK ITEMS

Refer to Parts List section for recommended stock
items. Stock Items are clearly identified with a bullet
preceding the parts description. See example below:
OPERATION
19

Publicité

loading

Ce manuel est également adapté pour:

609640609799