2. Connect spray gun to solution hose then connect
hose to coupler at front of machine (Figure 10).
FIG. 10
3. Turn the FORMULA ON/OFF lever to the ON
position, located at front of machine (Figure 11).
FIG. 11
NOTE: To operate spray gun at LOW PRESSURE
without the use of Formula cleaner, turn FORMULA
ON/OFF lever to the OFF position.
4. Adjust gun to low pressure by pushing spray
nozzle outward. Turn spray nozzle counter--
clockwise for fan spray pattern (Figure 12).
FIG. 12
5. Activate pump switch. Press vacuum/blower
switch towards vacuum symbol if using gulper tool
(Figure 13).
Quick Clean 1500 (03- -00)
FIG. 13
6. Starting at the furthest point in room, begin spraying
entire area from bottom to top working towards
machine. The cleaning agent (Formula 710) may
take up to 5 seconds before it starts to inject. After
spraying entire area, turn machine off and allow
cleaner to work for 5--10 minutes (Figure 14).
FIG. 14
NOTE: It may take pump 5- -10 seconds to prime.
Nozzle must be set at low pressure in order for pump
to prime.
FOR SAFETY: When using machine, do not spray
solution into electrical outlets, switches, fuse
boxes or on electrical appliances.
NOTE: After applying cleaner, turn the FORMULA
ON/OFF lever to the OFF position and rinse gun of
cleaning formula.