V. Technical Drawing
1. OIL DRAIN VALVE 
2. SIGHT GLASS 
3. HOUSING 
4. PUMP BACK COVER 
5. PUMP BACK ROTOR 
6. BACK ROTARY VANE 
7. PUMP BACK STATOR 
8. MIDDLE FENCE 
9. FRONT ROTARY VANE 
10. PUMP FRONT ROTOR 
11. PUMP FRONT STATOR 
VI. Technical Parameter
Two stages vacuum pumps 
Models 
Frequency 
Flow rate 
Ultimate vacuum 
Stage 
Power 
Inlet port 
Oil capacity 
Dimensions (mm) 
Weight 
12. PUMP FRONT COVER 
13. TRESTLE 
14. RUBBER FOOT 
15. BASE 
16. MOTOR HULL 
17. MOTOR STATOR 
18. BEARING 
19. MOTOR ROTOR 
20. MOTOR COVER 
21. FAN 
22. FAN COVER 
VP230 
50 Hz 
60 Hz 
71L/min  85L/min  142L/min  170L/min 
‐1 
3x10
Pa 
1/3 HP 
1/4" & 3/8" SAE 
300 ml 
280x115x230 
7.8 kg 
23. POWER SWITCH 
24. SOCKET 
25. CAPACITOR BOX 
26. CAPACITOR 
27. HANDLE 
28. INLET FITTING 
29. SCREW 
30. RETAINER 
31. VALVE PLATE 
32. CAP BOARD 
33. EXHAUST FITTING 
VP260 
50 Hz 
60 Hz 
‐1 
3x10
Pa 
1/2 HP 
1/4" & 3/8" SAE 
330ml 
320x125x230 
9kg 