Operator's Manual PP 455E
Assembling/Installing
equipment
When the machine has been transported to a suitable site,
it should be connected:
1. Check the hydraulic fluid level in the power unit. This is
checked with the level indicator.
Min. level = red line
Max. level = black line
Do not exceed the max. level when filling the tank with
hydraulic fluid. The hydraulic fluid expands when it
gets hot and can overflow if the level is too high. Tank
volume 16 l (4.2 US gallons).
2. Connect the incoming power cable (400 V, 63 A or 400
V, 32 A European connector). The cable must be
three-phase and earthed. When the machine is
equipped with a single phase socket there must also
be a neutral otherwise the single phase socket on the
distribution box will not work.
The power unit must be connected through a 63 A fuse
in order to use maximum power. If connected through
a 32 A fuse, the saw must be operated at low pressure,
and with that cut less effectively to avoid overloading
the fuse.
Assembling/Installing equipment
3. Connect the incoming water hose to the water coupling
on the bottom of the motor front on the hydraulic unit .
4. Connect the remote control using the supplied Canbus
cable. Tighten the cable connector screws by hand.
When the machine is equipped with a radio, a radio
antenna can be connected instead of a Canbus cable.
This is screwed into the same socket as where the
Canbus cable should have been fitted.
Fit the hydraulic unit
1. Check that the emergency stop switches on the unit
and the remote control have not been actuated by
turning them in the direction of the arrow.
When everything is okay the remote control's display
shows "Connect the hose assembly".
English - 15