lock-n-load.info/pages/misc/videos.html
How to Bulk Load L1175L
Manual Grease Filler Pump Loading Procedure
1. Make sure the barrel's follower rod is unlocked and
pushed in.
2. Wipe bulk filler nipple clean.
3. Insert the grease gun bulk filler nipple into loader
pump / transfer pump receptacle.
4. Pump grease until you reach a distance of 8 inches
between the follower rod handle and the black
barrel cap.
IMPORTANT:
Read all instructions and warnings before operating this product.
SAVE THESE INSTRUCTIONS! READ ALL INSTRUCTIONS!
WARNING:
• Do not attempt to remove the inlet valve or the internal piston assembly. Reassembly of these
components must be performed by trained service technicians to prevent damage. Other
attempts to repair or modify will void warranty.
OPERATION TIPS:
• When full stroke of the handle is not possible due to limited space, variable (short) strokes may
be used to deliver grease at proportionally lower displacement per stroke.
• The Automatic bleeder will expel air pockets when reconnecting the barrel and head, this will
greatly reduce air locks and priming problems.
IMPORTANT: Do not load gun with air-operated grease pump. Damage to unit will occur and
warranty will be voided.
Watch the Lock-n-Load Loading Demo:
Suction Loading Procedure
1. See step 1 on previous page to disengage gun barrel.
2. Insert open end of gun barrel two inches below surface
of grease.
3. Slowly pull back plunger rod handle (drawing in grease).
Then move follower rod handle to the side to lock it.
4. See step 2 on previous page to engage barrel into head
assembly.
5. Move follower rod handle to the center to unlock it
& push into barrel. Depress bleeder valve button to
release air.