8880429
STORAGE
When not in use for an extended period, apply a thin coat of lubricant
to the steel parts to avoid rust. Remove the lubricant before using the
tool again.
DISPOSAL
Recycle a tool damaged beyond repair at the appropriate facility.
Contact your local municipality for a list of disposal facilities or by-laws
for electronic devices, batteries, oil or other toxic liquids.
IMPORTANT! DO NOT pollute the environment by allowing
uncontrolled discharge of waste oil.
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does not
function properly or parts are missing. If unable to do so, have a
qualified technician service the tool.
PROBLEM(S)
Motor
overheats.
Motor does not
turn on.
Motor runs, but
steel cable
drum does not
turn.
Motor runs
slowly or
without normal
power.
14
1,500 LB 120V AC ELECTRIC WINCH
POSSIBLE CAUSE(S)
1. Incorrect power
cord.
2. Winch running time
too long.
1. Solenoid
malfunctioning.
2. Remote damaged.
3. Defective motor.
4. Internal damage or
wear.
Clutch not engaged.
1. Insufficient current
or voltage.
2. Incorrect power
cords.
For technical questions call 1-800-665-8685
SUGGESTED SOLUTION(S)
1. Use only supplied power cord.
2. Allow winch to cool down
periodically.
1. Tap solenoid to loosen
contacts.
2. Replace remote.
3. Check for voltage at armature
port with switch pressed. If
voltage is present, replace
motor.
4. Have technician service winch.
Move the clutch handle to the
engaged position. If problem
persists, a qualified technician
needs to check and repair.
1. Connect to appropriate power
supply.
2. Use only supplied power cords.
V1.0