USE OF THE REFRIGERATION SYSTEM - DESCRIPTION OF THE CONTROLS

Control device

CLOCK KEY:
- Displays the compressor oper-
ation hour count
- When an alarm condition is resolved, it re-
sets the alarm label itself
DEFROST KEY:
- Activates the manual defrost
device
SET KEY:
- Accesses the set point
- Pressing this button together
with the DOWN or UP KEYS lets you ac-
cess or exit the programming Menu
- Confirms the programming commands
16
Fig. 2
DISPLAY:
- Displays in °C the temperature detected inside the
refrigeration cell as well as the set point
UP KEY:
- Scrolls through the Menu items
- Increases settings
- Pressing this button together with the SET
KEY lets you exit the programming menu
- Pressing this button together with the
DOWN KEY locks the keypad
DOWN KEY:
- Scrolls through the Menu items
- Decreases settings
- Pressing this button together with the SET
KEY lets you enter the programming menu
- Pressing this button together with the UP KEY
locks the keypad
ON / OFF KEY:
- Activates/deactivates the refrigera-
tion system
ENGLISH
COMPRESSOR LED
DEFROST LED
CONTINUOUS
CYCLE LED
ALARM LED
LED
ON
Flashing
+
+
+
Active Leds
FAN LED
CLOCK LED
DECIMAL LED
FUNCTION
Compressor enabled
Anti-short cycle delay enabled
Programming Phase
Heat function enabled
Defrost enabled
Drip time in progress
Fans enabled
Fans delay after defrost in progress
System malfunction
Continuous cycle running
Displays compressor operation hour count
Modifies set point