1. Quick user guide
A. Connect the charger to the battery.
B. Connect the charger to the wall socket. The TEST LED will indicate that
the mains cable is connected to the wall socket.
All charge status LEDs will flash in case of reverse polarity connection,
short-circuit or if a 12V charger is connected to a 24V battery.
The TEST LED will flash as long as a charge pulse does not increase battery
voltage to more than 12.5V resp. 25V.
When the TEST LED is on continuously, proceed to C.
C. If required, press the MODE-button or use a Bluetooth Smart device to
select another charge program.
When RECONDITION is selected in combination with NORMAL or HIGH;
the RECONDITION LED will be on, and the RECONDITION LED will flash
during reconditioning.
The charger can be switched to low current mode (see technical
specifications) by pressing the MODE button during 3 seconds. The MODE
LED will blink when in low current mode.
The low current mode remains activated until the MODE button is pressed
again during 3 seconds.
D. The battery is about 80% charged and ready for use when the absorption
LED switches on.
E. The battery is fully charged when the FLOAT or STORAGE LED is on.
F. Stop charging at any time by disconnecting the mains cable from the wall
socket.
Explanation icons