7. Technical Data
Model
De-humidification performance max.
De-humidification performance (AHAM)
Air output
Connection
Fuse
Power intake
Performance
Weight
Dimensions
Operating area
Filters
De-frosting
Pump
Condensate pumps, conveying height
Coolant
High pressure
Low pressure
Compressor
Noise level at 3 m distance
Attention:
The technical data can be modified without prior notification within the course of further
development. Some of the values are approximate values.
KT1800
(32° C/90%RH)
55.0l /24h
(27° C/60%RH)
31.7 l/24h
343 m³h
230 V / 50 Hz
16 A
3.2 A
0.69 kW
36 kg
830 x 500 x 500 mm
1 – 38 ° C
Plastic or paper
Automatic thawing (hot gas)
Centrifugal
6.1 m
R-410A / 369 g
16 bar
31 bar
Rotary piston compressor
55 dB
31
EN