Dehumidifier
KT 1800
Error display
If there are errors or interferences during operation, an error message "SERVICE
ERROR" appears on the display followed by "ER01" or another error number. Please
follow these Stepps (see point 9 operation display):
1. Pull the device plug from the mains and plug it back in again. The electronics
will re-set itself.
2. If the problem is not solved by doing this, see the following solutions
according to the table.
3. If the problem is still not solved, contact the Heylo Service Department under
Tel. No. 04202 / 9755-15.
ER
1-2-3-5-6
ER4
ER8
ER9
KW/h counter
The KW/h counter shows you the total status of used energy.
Please note the counter status before starting the job.
The red light on the counter shows you that usage is being measured.
The counter is counting 0.001 KW/h per blink impulse.
Problem with the electronic operating field. Inform the HEYLO service
department.
Problem with the temperature sensor or the cable.
Problem with a sensor control button. Press and release each button
several times.
Check for blockages in the pump or drainage hose and ensure that the
pump is connected properly.
28