Operating Instructions MSA 2
6
Technical characteristics
Mains voltage and frequency
Suggested power generators
Welding technique
Fusion voltage
Operating temperature
Internal temperature
Temperature sensor resolution
Fittings range
Fusion data input mode
Capacity of internal memory
USB Port
Protection factor
Dimensions
Weight
6.1
• ISO 12176-2
• ISO 12176-3 (MSA 2.1 only)
• ISO 13950
• EN 60335 (Safety)
• EN 61000-6-2/4 (EMC)
Standards
Technical characteristics
230 V (265V÷190V) 40÷70 Hz
3.5kVA
Voltage controlled
8÷42V (48 V)
- 20 °C / +50°C
- 20°C / +70°C
± 1°C
Ø20mm ÷ 1200mm
(others on request)
Bar code, manual
350 protocols (500 for MSA
2.1)
Type A
IP 65
280x280x420 mm (max)
11,9 kg
21