Error messages
5
Error messages
In case of anomalies or errors, the MSA 2.0/2.1 pops up a
specific message useful to identify the possible issue. The
related number will be even tracked within the welding protocol,
to give evidence of the accident.
The error message appears on the display with the following
format:
The table below summarizes all the messages managed by the
electro-fusion unit, with a brief explanation of the possible
causes.
ERR
DISPLAY
INDICATION
Vi
E1
E2
Vi
E3
Vi
E4
E5
-
E6
E7
i
E8
i
E9
E10
E11
Vo
E12
Vo
E13
E14
Io
E15
E16
20
E-1
Vi
MEANING
MAINS VOLTAGE TOO HIGH
MAINS VOLTAGE TOO LOW
OUTAGE DURING LAST FUSION
FUSION INTERRUPTED WITH
STOP BUTTON
AMBIENT TEMP. TOO LOW
AMBIENT TEMP. TOO HIGH
INTERNAL TEMP. TOO LOW
INTERNAL TEMP. TOO HIGH
FITTING RESISTANCE TOO LOW
FITTING RESISTANCE TOO HIGH
FUSION VOLTAGE TOO LOW
FUSION VOLTAGE TOO HIGH
FUSION CIRCUIT INTERRUPTED
FUSION CURRENT TOO HIGH
FITTING OUT OF RANGE
SYSTEM ERROR
Operating Instructions MSA 2
COMMENT
Generator voltage/freq. above the threshold
Generator voltage/freq. below the threshold
Power cord disconnected during last fusion
Fusion stopped by the user
Temp. sensor detected a value below the
threshold
Temp. sensor detected a value above the
threshold
EF unit cannot fuse, since it is too cold
EF needs to cool down, since it is too hot
Fitting faulty
Fitting faulty
Not enough power from mains
Internal circuit not calibrated or faulty
Power cord or output cables detached
during welding
Fitting broken or circuitry not calibrated or
faulty
Fitting is not in the right range
Electronic faults