Switching From ºc/24-Hour To ºf/12-Hour Indication; Possible Settings; Setting The Temperature; Setting The Timer Function - WANDERS COCOS Mode D'emploi Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Switching from ºC/24-hour to ºF/12-hour indication
Press the OFF button
12-hour indication) to the ºC (and the 24-hour indication), and vice versa.

Possible settings

By pressing the SET button
perature
timer
MAN.
MAN: this setting allows you to turn the flames manually higher or lower with the big-flame button
the small-flame button
Day temperature ( ): this mode allows you to set the desired daytime temperature; the remote control
set will function as a thermostat.
Night temperature ( ): this mode allows you to set the desired night temperature.
TIMER: this mode allows you to preset 2 switch-on and 2 switch-off times per 24 hours. If the night setting
is on - - -, the stove will burn on the pilot flame.

Setting the temperature

Select the day temperature or night temperature by briefly pressing SET button
Now press SET button
Preset the temperature with buttons
Wait or press OFF button
In order to save the batteries you are advised to reset the night-temperature until the display shows the
'- - -' signal.

Setting the timer function

Select the timer function by briefly pressing SET button
Now press the SET button
Set the hours with button
Briefly press SET button
Once all 4 timings have been set, press OFF button

Operation (remote control)

Igniting the fire

Open the gas turncock that is fixed in the gas pipe leading to the stove.
Press "O I" switch
on the gas control block in the "I" position.
Turn control button
Simultaneously press buttons
tic signal indicates the start, and is followed by short acoustic signals
(0.2 sec/signal, 1Hz.) until the pilot flame and the chief burner are ig-
nited. After the main burner has lit, the flame height will automatically
go to the maximum position.

Possible error messages

Long signals (0.8 sec. signal with 0.2 sec. interval) during lighting
empty. (After hearing this signal, you can switch on the appliance for about another 10 times.)
5 seconds continuous signal
is not in the "I" position.
5 short signals (0.2 sec. signal with 0.2 sec. interval)
failed. Possible cause: air in the pilot burner pipe.
Important: If the pilot flame has gone out you must wait at least 5 MINUTES before repeating the
!
above-mentioned steps.
and the small flame button
you can switch quickly between MAN
.
longer until the display starts flashing.
or
(5 ºC is the minimum day temperature).
to switch back to the thermostat-controlled system.
longer until P1 ( ) starts flashing.
and the minutes with button
for the next timing.
on the gas control block to the ON position.
and
on the handset. A short acous-
: error message. One of the cables may not be connected, or the "O I" switch
simultaneously (2 sec) to switch from ºF (and the
day temperature
a few times.
.
to end the presetting.
: batteries of the receiver are almost
: ignition of the pilot flame and the main burner has
night tem-
or
.
19

Publicité

Table des Matières
loading

Table des Matières