Operating Temperature: 32°F to 104°F (0°C to 40°C)
Storage Temperature: 14°F to 122°F (–10°C to 50°C)
Weight: 145 g
Size: 104 x 55 x 32.5 mm
Standard: IEC1010 CAT III 1.000 V Pollution degree II, CE Approved
AC/DC voltage measurements
Caution:
Do not measure AC/DC voltages if a motor on the
circuit is being switched ON or OFF. Large voltage
surges may occur that can damage the meter.
Set the function switch to the green V position.
Press the MODE button to indicate "DC" or "AC"
on the display.
Touch the black test probe tip to the negative side
of the circuit.
Touch the red test probe tip to the positive side of
the circuit.
Read the voltage in the display.
DC/AC current measurements
Set the function switch to the µA/mA position.
For current measurements up to 2000uA DC/AC,
set the function switch to the mA position
Press the MODE button to indicate "DC" / "AC"
on the display.
Remove power from the circuit under test, then
open up the circuit at the point where you wish to
measure current.
Touch the black test probe tip to the negative side
of the circuit.Touch the red test probe tip to the
positive side of the circuit.
Apply power to the circuit.
Read the current in the display
2011-0583 0715 53 390_Multimetro Digital_User Manual_110726.indd 9
Operation
Resistance measurement
Warning:
To avoid electric shock, disconnect power to the
unit under test and discharge all capacitors before
taking any resistance measurements.
Remove the batteries and unplug the line cords.
Set the function switch to the Ω position.
Touch the test probe tips across the circuit or part
under test. It is best to disconnect one side of
the part under test so the rest of the circuit will not
interfere with the resistance reading.
Read the resistance in the display.
Continuity check
Warning:
To avoid electric shock, never measure continuity
on circuits or wires that have voltage on them.
Set the function switch to the
Press the MAX button to indicate
Touch the test probe tips to the circuit or wire you
wish to check.
If the resistance is less than approximately 150 Ω,
the audible signal will sound. If the circuit is open,
the display will indicate "OL".
Diode test
Set the function switch to the
Press the MODE button to indicate
display.
position.
on the display.
position.
on the
9