Flashlight; Hold Button - Würth 0715 53 390 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
Touch the test probes to the diode under test
Forward voltage will typically indicate 0.400
to 0.700 V. Reverse voltage will indicate "OL".
Measurements
Warning:
Risk of Electrocution. Before use, always test the
Voltage Detector on a known live circuit to verify
proper operation.
Touch the probe tip to the hot conductor or insert
into the hot side of the electrical outlet.
If AC voltage is present, the detector light will
illuminate.
Note
:
The conductors in electrical cord sets are often
twisted. For best results, rub the probe tip along a
length of the cord to assure placing the tip in close
proximity to the live conductor.
The detector is designed with high sensitivity. Static
electricity or other sources of energy may randomly
trip the sensor. This is normal operation.

Hold button

The Data Hold function allows the meter to "freeze" a
measurement for later reference.
Press the "DATA HOLD" button to "freeze" the
display, the "HOLD" indicator will appear.
Press the "DATA HOLD" button to return to normal
operation.
10
2011-0583 0715 53 390_Multimetro Digital_User Manual_110726.indd 10
Shorted devices will indicate near 0 V and an open
device will indicate "OL" in both polarities.
Non-Contact AC Voltage

Flashlight

Press and hold the top button to turn the flashlight on.
Release the button to turn the flashlight off.
Auto power off
The auto off feature will turn the meter off after 15
minutes.
Replacing the battery
Remove the bottom cover and secure the screw.
Replace old battery with fresh two 1.5 V AAA type
battery (Art. 0827 01).
Replace the bottom cover and secure the screw.
7/26/2011 5:04:16 PM

Publicité

Table des Matières
loading

Table des Matières