Filter Pressure Is Below The Pressure Indicated By The Blue Hand; Filter Pressure Rises Out Of The Green Zone - BWT RTM HF S-500 Notice D'installation Et Conseils D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.1.1 Filter pressure is below the pressure indicated by the blue hand

Clean the filter basket and the skimmers
Stop the pump,
P ut the 6-way multiport valve to "CLOSED",
C lose the suction valves A, B, C, D (skimmers, main drain) and the return fitting valve E,
O pen the prefilter and take out the basket,
U sing a jet of water remove any debris,
P ut the basket back,
R eplace the lid of the prefilter making sure that the seal is correctly positioned and that there is enough
water to prime the pump,
C lean out the skimmers.
P ut the 6-way multiport valve to "FILTRATION",
O pen the suction valves A, B, C, D (skimmers, main drain) and the return fitting valve E,
R estart the pump,
P urge air from the filter.
This operation should be carried out each time the pool is vacuumed using a brush on a suction line, and
at least once a week.
4.1.2 Filter pressure rises out of the green zone
Backwash the filter
Stop the filter,
C heck the prefilter for debris. (If there is a build-up of dirt clean it out as described above),
P ut the 6-way multiport valve to the "WASH" position,
O pen the 1/4 turn valve (F) on the outflow pipe,
T urn the motor on,
M onitor the water colour through the turbidity sight glass on the 6-way multiport valve.
CAUTION
Cleaning will start after a few seconds. (The water becomes very cloudy)
As soon as the water in the turbidity sight glass becomes clear, stop the pump,
P ut the 6-way multiport valve to the "RINSE" position,
T urn the pump on for about 20 to 30 seconds. The purpose of this step is to evacuate any remaining
impurities and settle the sand,
S top the pump,
P ut the 6-way multiport valve to the "FILTRATION" position,
R estart the pump,
C lose the 1/4 turn valve (F) on the waste line.
After back washing, the black hand on the pressure gauge should be realigned with the blue hand, that
is the pressure reading should return to the nominal pressure
In the event that the pressure indicated by the pressure gauge does not drop after back washing the
filter once (or even twice) contact your installer.
CONSTRUCTION & RÉNOVATION
2021/01 - Indice de révision : I - Code : 26680
21/36

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rtm hf s-610-aRtm hf s-610-bRtm hf s-760Rtm hf s-920

Table des Matières