• At low temperatures below +5 °C, sluggishness
may make starting difficult or impossible.
8.9 Switching ON/OFF (fig. 1)
• To switch on the compressor, pull the ON/OFF
switch (8) upwards.
• To switch off the compressor, press the ON/OFF
switch (8) down.
8.10 Setting the pressure (fig. 2)
• You can adjust the pressure on the pressure gauge
(6) using the pressure regulator (7).
• The set pressure can be taken from the quick lock
coupling (5).
Setting the pressure switch
• The pressure switch is set at the factory.
Cut-in pressure approx. 8 bar
Cut-out pressure approx. 10 bar.
It is strictly forbidden to remove protective devices,
pressure regulators or electrical components from
your device.
9. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer's mains connection as well as the ex-
tension cable used must also comply with these
regulations.
When working with spray attachments and during
temporary use outdoors, the device must be connect-
ed to a residual current circuit breaker with a trigger
current of 30 mA or less.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
24 | GB
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking H05VV-F.
The printing of the type designation on the connec-
tion cable is mandatory.
• The product meets the requirements of EN 61000-
3-11 and is subject to special connection condi-
tions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavorable conditions in the power supply
the product can cause the voltage to fluctuate tem-
porarily.
• The product is intended solely for use at connec-
tion points that
a. do not exceed a maximum permitted supply im-
pedance "Zmax = 0.382 Ω", or
b. have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate
10. Cleaning, maintenance, storage
and transport
m Warning
Pull out the power plug before doing any cleaning and
maintenance work on the equipment. Risk of injury
from electric shock!
m Warning
Wait until the equipment has cooled down complete-
ly! Risk of burns!
m Warning
Always depressurize the equipment before carrying
out any cleaning and maintenance work! Risk of in-
jury!