Connection of the
circulation pump, pool
circuit (GP9)
Connect the circulation pump (GP9) to AA5-X9:8 (230
V), AA5-X9:7 (N) and X1:3 (PE).
Unit box External
9
8
7
6
5
4
3
2
1
AA5-X9
1
2
3
X1
Connection of the
circulation pump,
climate system (GP10)
If the climate system does not already have an external
pump, one can be connected to the accessory card.
Connect the circulation pump (GP10) to AA5-X9:2 (230
V), AA5-X9:1 (N) and X1:3 (PE).
Unit box External
4
3
L
2
N
1
PE
AA5-X9
1
2
3
X1
POOL 40 | GB
GP9
GP10
Connection of the
reversing valve motor
(QN19)
Connect the motor (QN19) to AA5-X9:6 (signal), AA5-
X9:5 (N) and AA5-X10:2 (230 V).
9
Unit box External
8
7
9
AA5-X9
8
6
7
5
Black
6
4
Blue
5
3
Brown
4
2
3
2
1
1
-X10
-X10
2
1
AA5-X10
DIP switch
The DIP switch on the accessory card must be set as
follows.
Pool 1
Pool 2
QN19
AA5-S2
-X9
9
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
8
-X8
-X2
7
6
5
-X4
4
1
3
2
2
3
1
4
-X10
5
6
-X1
7
N
8
L
PE
PE
21