Hot Water Connection; Condensate Evacuation; Air Connection - Thermor AEROMAX VM Notice D'utilisation Et D'installation

Masquer les pouces Voir aussi pour AEROMAX VM:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.2. Hot water connection

Do not connect copper tubes directly on the tank connection. You have to fit the supplied insulation
union (included in the supply).
In case that the tank connection is corroded without this protection the warranty will not apply.
If the installation is made with synthetic pipes (e.g. : PER, multi-layer...), install mandatory a
thermostatic control valve at the connection pipes of the water heater. The setting should be done in
relation with the specification of the installed piping.

6.3. Condensate evacuation

The temperature drop of the air passing through the exchanger forms condensation from humidity
in the air. The condensed water is evacuated on the rear of the tank using the supplied plastic tube.
The use of a siphon to connect to sew water is mandatory (the siphon must not be made with the
supplied tube)

7. Air connection

The use of insulated ducts is mandatory.
If the water heater is ducted the parameter setting has to be adapted.
The total pressure drop of ducts and accessories for air intake and exit has to be less than 70 Pa. The
recommended length of ducts has to be respected.
up to 0,25l/h of condensation

Publicité

Table des Matières
loading

Table des Matières