Mounting Instructions; Maintenance Instructions - Chicago Pneumatic 3747 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
Safety Information
Product Specific Instructions
Description
1
Battery charge level
2
Warning LED
3
Connector
4
Daisy-chain output
4
Power supply plug

Mounting instructions

Installing the charger on a wall
Use the following drilling template.
mm
A
156
B
102
Mount the battery pack charger as follows.
Use M5 screws (not supplied).
Daisy-chain connection
Daisy-chain connection
Refer to the chapter Technical data [Page 3] to know how
many chargers can be daisy-chained.
6
in.
6.14
4.02
© Chicago Pneumatic - 8940176356
For example:
1.
Daisy-chain the chargers as shown above.
Use the optional dedicated cable (length: 30 cm (11.81
in.) ; part number: 6158133830).
2.
Plug the last charger to the mains.
Powering on
Use the following power cords to power supply the battery
pack charger.
Area
Length
Europe
2.5 m
8.2 ft
USA
2.5 m
8.2 ft
UK
2.5 m
8.2 ft
China
2.5 m
8.2 ft
Use only the power cord supplied.
1
Plug for power cord
Connect the power cord to the charger and plug it to the
mains.
The 4 white LEDs light up and then go out.
The warning LED lights up in red, turns orange and then
goes out.

Maintenance instructions

1.
Disconnect the charger from any AC outlet before
cleaning.
2.
Clean out dust and debris from charger vents and elec-
trical contacts. Use a damp cloth.
3.
Do not use liquid or spray detergent for cleaning.
Do not modify or attempt to repair the charger.
For safety reasons, the charger should be serviced only by
the manufacturer or authorized service providers.
CHARGER
Part number
6159172010
6159172030
6159172020
6159172060

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cp18-36ch

Table des Matières