6. CONTROLS

Inverter Models Only

The Display controls general operation. The layout, main
functions and buttons are shown below.
HEATING
Figure 12. Operation Display, Models -30-I through -65-I
Symbol Designation
ON/OFF
Speed
Up
Down
Table E.
Display Button Functions
Power On
Press the LOCK button
then press POWER
Adjust/Set Temperature:
When screen is unlocked, press UP
display or adjust the set temperature.
To change from Fahrenheit to Celsius, press the
the
for 3 seconds.
Smart/Silent mode selection
Smart mode, as default, will be activated when the HEAT
PUMP is on, and the screen shows
Press FAN
to enter Silent Mode. The display screen
will show
.
NOTE: Select Smart Mode for initial heating.
20
COMPRESSOR
HEATING
CAPACITY %
Button Functions
Press 3 seconds to unlock/lock
screen
Power On/Off
Smart/Silent Mode
Temperature Adjustment
Temperature Adjustment
for 3 seconds to light up screen,
to power on the heater.
or DOWN
.
UNCONTROLLED DOCUMENT IF PRINTED
APPROVED
Screen Lock
If no button is used within 30 seconds, the screen will lock
automatically. At this point the backlight will turn off and 0%
will display.
Alternatively you can lock the display by pressing the
LOCK button
for 3 seconds to achieve the same result.
To unlock the screen and use any other button, follow the
Power On instruction above.
Defrosting
Auto Defrosting:
1. When the heater is defrosting, HEATING
continually flash.
2. After defrosting, HEATING
Manual Defrosting:
1. When heater is heating, press FAN
together for 5 seconds to start manual defrosting,
will flash continuously.
After defrosting, HEATING
NOTE: Manual defrosting intervals should be more than
30 minutes and the compressor should run for more
than 10 minutes.
Heat, Cool or Auto Mode
1. Press the Lock button for 3 seconds to light the
screen.
2. Press the Lock button to change the Heat Pump
operating MODE.
MODES:
POOL HEAT (sun icon) Heat to set point
POOL COOL (snow icon) Cool to set point
POOL AUTO (triangle icon) Heat or Cool to set point.
to
and
will
will stop flashing.
and MINUS
will stop flashing.