To enter the SmartLink menu, press the LEFT and RIGHT Arrow keys on the
CPAP keypad at the same time. To exit the SmartLink menu, press the same
key sequence again or simply turn the CPAP off and on.
Press the UP or DOWN arrow key on the CPAP keypad to adjust the volume
for the audible alert notification.
This menu displays the serial number of the SmartLink module connected to
the CPAP.
This menu displays the operating firmware version of the SmartLink module
connected to the CPAP.
This menu displays the pulse oximetry (SpO2) and pulse rate (PR) information
when a pulse oximeter is used with the system. If a pulse oximeter is not
connected to the module "***" will be displayed for the SpO2 and PR values.

data Retrieval

Your clinician may have a standard protocol to follow-up on your therapy to find out how the device is working
and to identify any problems or issues you may be having. Your home care provider will mail a SmartLink Data
Card to you at certain intervals and ask you to download the data onto the card and mail it back. It is a very
simple process:
1.
Ensure that the SmartLink module is properly connected to the CPAP and that the CPAP is connected to
an appropriate power source.
Orient that card as shown in Figure 4. Insert and press the card into the card slot located on the top of
2.
the module until the card clicks into place Figure 5.
3.
Ensure that the card is detected (view message or audible alert) and allow the data to transfer to the
card. Depending on the amount of data, this could take several minutes. Do not remove the card from
the module until complete. Observe the message(s) on the display to confirm that the transfer was
successful (see Messages below). If necessary, contact your provider and report any errors that may
have occurred.
4.
If instructed by your provider, eject the card from the card slot by pressing down on the card until it is
released and remove the card from the slot.
5.
Place the card in the provided mailer and return it to the provider.
Messages
The following messages could be displayed on the CPAP during the data retrieval process:
Message shown when a card is first inserted into the SmartLink Module and
data is being transferred. This message will remain on the display until transfer
is completed.
Message shown when a card is first inserted into SmartLink Module and there
is no new data to transfer. Will remain on display for ten seconds.
Message shown after completion of card data transfer. This message will
remain on the display for ten seconds.
Message shown if an error is encountered during card data transfer. This
message will remain on the display until acknowledged by pressing any key on
the keypad or a 15 minute timeout occurs.
A-DV5M-1
SmartLink Menu
Press   To Exit
Volume
100% (Adjust )
Serial Number
CM123456
Firmware Version
V0.06 25/04/2008
SpO2:
100
PR:
101
Card Detected
Please Wait . . .
Card Detected
Ready For Use
Card Transfer
Successful
Card Error
Contact Provider
EN - 7