POWER MANAGEMENT FEATURE

The power management feature of this product complies with every power saving requirement of
®
E
S
and VESA DPMS. When activated, it automatically reduces unnecessary power
NERGY
TAR
consumption of the monitor when your computer is not in use.
To use the feature, the monitor needs to be connected to a VESA DPMS compliant computer. There
is a power management step the monitor takes as described below. The power management function,
including any timer settings is configured by the operating system. Check your operating system
manual for information on how this can be configured.
n
Power Management Mode
When the H-sync signal / V-sync signal / H and V sync signals from the computer are off, the
monitor enters into Power Management Mode which reduces the power consumption to less than
5W. The screen becomes dark, and the power indicator turns to orange. From Power Management
Mode, the image reappears in several seconds when either the keyboard or the mouse are
touched again.
NORMAL MODE
POWER MANAGEMENT MODE
n
Even when using the power management mode, the monitor consumes electricity. Turn
NOTE
off the Power Switch whenever the monitor is not in use, during the night and weekends,
to avoid unnecessary power consumption.
n
It is possible that the video signal from the computer may be on while the H or V sync
signal is missing. In this instance, the POWER MANAGEMENT feature may not work
properly.
n
Video input does not provide the POWER MANAGEMENT feature.
Power Indicator
Green
Orange
POWER
0
5 W
CONSUMPTION
100%