Westward Operating Instructions and Parts Manual
injury can occur. Unplug the compressor before attempting any repairs.
Troubleshooting Chart
Symptom (s)
Air Leaks
Compressor is not
delivering enough air.
Motor will not run.
Compact Air Compressor
Voltage sources, moving parts, or compressed air sources
are exposed when repairing the compressor. Personal
Possible Causes (s)
1.
Hose fitting loose.
1.
Prolonged excessive
use of air.
2.
Hole in hose.
3.
Air leaks.
1.
Fuse blown, circuit
breaker tripped.
13- ENG
Model 3JR69
Corrective Actions (s)
1.
Tighten fitting.
1.
Decrease the amount
of air usage. Your
compressor is not
large enough for the
air requirement.
2.
Replace the hose.
3.
Tighten fittings.
1a. Check fuse box for
blown fuse and
replace as necessary.
Reset circuit breaker.
Do not use a fuse or
circuit breaker with
higher rating than
that specified for your
particular branch
circuit.
b.
Check for proper
fuse. You should be
using a
"Time Delay" fuse.
c.
Check for low voltage
problem.
d.
Check the extension
cord.
e.
Disconnect the other
electrical appliances
from circuit or
operate the
compressor on its
own branch circuit.