Tightness inspection

Hoses check
Make sure the connecting hoses (Fig. 12) are in a good
condition and correctly fixed.
If the hoses are damaged, broken or badly connected to the
unions, they must be replaced.
When sticky materials are treated, check for possible
clogging along the hose, in the inlet and on the baffle plate
inside the filtering chamber.
Scrape inlet (2 - Fig. 12) from the outside and remove the
deposited waste as indicated in figure 12.
Filtering chamber tightness check
If gasket (1 - Fig. 13) between container (4) and filter
chamber (3) fails to guarantee a good seal:
Loosen the four screws (2) that lock the filtering
chamber (3) against the vacuum cleaner structure.
Allow the filtering chamber (3) to lower down and tighten
the screws (2) once it has reached the tightness position.
If an optimal seal cannot be obtained and the gasket is torn
or cracked, etc. it must be replaced.

Wiring diagram list

Figure 14
1.
Compressor
2.
Motor head
Q1.
Main switch
TS2.
Cyclic timer
TR1.
Transformer
M1.
Clamp
XC2.
Connector
H2.
Light intervention of the compressor motor
protection
www.blastrac.com ‒ info@blastrac.com