Instruction manual BDC-24-230V-P
Vacuum cleaner operation
The air speed in the suction tube must not be less
than 20 m/s.
This state is shown by the green indicator of the
primary filter.
When using the vacuum cleaner, check:
■
The state of the max. vacuumed material level indicator
(6 - Fig. 4) if the level check is installed.
■
The state of the primary filter (8 - Fig. 4) and the
absolute filter (if installed) (9 - Fig. 4).
If one of the indicators is lit, follow the instructions.
Indicator
Symbol
signal
MAX
Max. vacuumed
material level
(6 - Fig. 4)
ar/psi
Primary filter
(8 - Fig. 4)
Absolute filter
(9 - Fig. 4)
I
Consult the "Troubleshooting" chapter if faults
occur.
US
WARNING!
WARNING!
Vacuum cleaner
Indicator
state and
colour
procedure
Suction stopped.
Empty the container
Red
(see relevant
paragraph).
Suction on.
Replace the cartridge
Red
filters.
(see relevant
paragraph).
Suction on.
Change absolute filter
Red
(see relevant
paragraph).
WARNING!
Primary cartridge filters operation
Figure 6
1.
Electropneumatic device
2.
Filter cartridges
3.
Timer
The filtering cartridges (2) serve the purpose of filtering
the intake air. The vacuum cleaner is equipped with a fully
automatic electropneumatic device (1) to alternately clean
the filtering cartridges (2) which guarantees continuous
service; powered with a 24V rating, is complete with cyclic
timer (3) to regulate the following times:
T3= time between one cleaning cycle and the next, set on 0
seconds;
T2= time between one cleaning operation of the cartridge
(2) and the next, set on 20 seconds;
T1= opening time of the solenoid valve for backwashed air
exhaust into the cartridge, set at 1 tenths of a second.
The shorter the time, the more energetic the cleaning
action will be.
Factory setting should not be changed if without
consulting Blastrac.
The three solenoid valves of the electropneumatic device
control the cleaning of the relative filter cartridges.
Figure 6A
1.
Filter cleaning solenoid valve E1
2.
Filter cleaning solenoid valve E2
3.
Filter cleaning solenoid valve E3
Emergency stopping
Press Stop button (5 - Fig. 4). The vacuum cleaner stops.
WARNING!
The motors and internal components of the vacuum
cleaner will still be electrically powered.
To start the vacuum cleaner, see the starting and stopping
paragraph
Emptying the dust container
WARNING!
Before proceeding with these operations, turn
■
the vacuum cleaner off and disconnect the plug
from the power socket.
Check the class of the vacuum cleaner.
■
■
Version not suitable for vacuuming hazardous dust
▪
Release dust container (1 - Fig. 7), with lever (2),
then remove and empty it.
▪
Make sure the seal is in perfect condition and
correctly positioned.
▪
Place the container back in position and secure it
again.