STORAGE CHARGE LIPO/LIFE
To avoid loss of performance and/or permanent damage,
LiPo and LiFe batteries must be stored charged at 50%
(not full or empty). The charger features a storage charge
that charges the batteries at 50% of their capacity (3.85V/
cell for LiPo and 3.3V/cell for LiFe).
Procedure
 Select the charge channel, 1 or 2.
 Select memory profile 1 to 5, select STR mode
and adjust the charge settings.
 Connect the battery to the charger using the
charge leads
 Connect the balancing plug to the appropriate
correct port
 Press the START/STOP key to start the charge.
 Once the storage charge is completed, press the
START/STOP key to display the final charge data.
 Press START/STOP key to return to the main screen.
 Disconnect the battery.
NOTE: Storage mode will only function if the batteries
are charged below 50%. The charger cannot discharge
batteries.
www.teamorion.com

ADVANCED SETTINGS

The advanced settings allow to fine-tune the charger's
function. You do not need to modify these settings for
standard use. To enter the advanced settings menu, press
the SET/MODE key from the main screen and then use
the ENTER and +/- keys to select and modify the settings.
Power allocation
This setting changes the power output balance between
the two charge channels (by default the power to channel
1 and 2 is the same). If you charge a higher voltage battery
like a 4S LiPo battery, allocating more power to the channel
will allow for a higher effective charge current and therefore
a faster charge. When you press the SET key, the setting
and channel number flash, using the + and – keys you can
increase or decrease the power attributed to the current
charge channel.
Key Beep
Allows the user to switch the beep tone on/off.
Safety Timer
The safety timer interrupts the charger's function when
the set time is reached. The default setting is 120 minutes
and can be adjusted from 10 to 240 minutes. For improved
safety we recommend using the shortest time possible
which still allows for a full charge of your batteries.