EWM1 V2 device.
4. FAULT INDICATIONS
For safety and protection purposes, EWM1 V2 will instantly
power down/prevent from powering up the electrical appliance
plugged into EWM1 V2 outlet when the following faults are pres-
ent:
• OVERVOLTAGE – voltage has increased above 260VAC.
• UNDERVOLTAGE – voltage has dropped below 190VAC.
• OVERCURRENT – current has increased above 12,5A.
• RELAY FAULT – unable to power up the appliance due to
faulty relay.
• TEMP. FAULT – the environmental temperature has dropped
below -35°C (-31°F) or increased above +90°C (+194°F).
In addition, the user can view the existing faults by EKB2 key pad
(only for ESIM364/ESIM384) or by accessing the ELDES Secu-
rity app account. In order to clear the existing faults, please press
the
button on EWM1 V2, turn OFF the electrical appliance or
turn OFF the wireless PGM output associated with EWM1 V2.
8
EN