Installation

5.3 Gas connection

CAUTION!
Check this data before connecting the appliance to the gas
cylinder. Pressure reducing valves to be used between the gas
cylinder and the appliance must conform to the categories listed
in the table below.
This appliance can be operated with the gases and related pressures
described in the following table. The identification label glued to the appliance
clearly shows the category (or categories) according to which the appliance
has been adjusted.
CATEGORY AND COUNTRIES OF
DESTINATION
AT BE DE DK FI GB NL NO PT SE SI
I3+ (28-30/37)
BE CH ES FR GB IE IT PT SI
MODEL
OG2000
OG3000
CAUTION!
During installation and connection, the gas conductor of the
appliance must not be subject to twisting, pulling or other stresses.
32
I3B/P(30)
NOMINAL AND
COMPLETE HEAT
OUTPUT
kW - gr/h
1.6 - 116
OG2000 - OG3000
GAS PRESSURE
30 mbar Butane (G30)
30 mbar Propane (G31)
28-30 mbar Butane (G30)
37 mbar Propane (G31)
VOLUME OF AIR
REQUIRED FOR
COMBUSTION
m
/h
3
3.2