4.

Choosing Installation Site

* Locate the appliance in an area where leakage from the boiler or connections will not result in dam-
age to the area adjacent to the appliance or to the lower floors of the structure. When such locations
cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed
under the appliance. The pan must not restrict combustion air flow.
* Install this boiler in a way that the constituent parts of the gas ignition system are protected from water
(water drops, spray, rain, etc.) during device operation and repair (circulator replacement, drain trap
or control device replacement, etc.).
• Locate the vent terminal so that there are no obstacles around the termination and so that ex-
haust can't accumulate. Do not enclose the termination with corrugated metal or other materials.
• The boiler is designed for indoor installation only. Never install it
outdoors or in a bathroom, it may be damaged or a fire may be
caused.
• Avoid places where fires are common, such as those where
gasoline, benzene and adhesives are handled, or places in which
corrosive gases (ammonia, chlorine, sulfur, ethylene compounds,
acids) are present.
Using the incorrect voltage may result in fire or cracking.
• Avoid installation in places where special chemical agents
(e.g., hair spray or spray detergent) are used.
Ignition failures and malfunction may occur as a result.
• Carbon Monoxide Poisoning Hazard. Do not install this boiler in a
mobile home, recreation vehicle or on a boat.
• Consult with the customer concerning the location of installation.
• Install the boiler in an area that allows for the proper clearances to combustible and noncombus-
tible construction. Consult the rating plate on the appliance for proper clearances.
• Avoid installation in places where dust or debris will accumulate.
Dust may block the air-supply opening, causing the performance of the device fan to drop and
incomplete combustion to occur as a result.
• Do not install the boiler in a place where it may be threatened by falling objects, such as under
shelves.
• The boiler must be installed in a place where supply and exhaust pipes can be installed as
directed.
• Do not install the boiler where the exhaust will blow on outer walls or material not resistant to
heat. Also consider the surrounding trees and animals.
The heat and moisture from the boiler may cause discoloration of walls and resinous materials,
or corrosion of aluminum materials.