For the Fitter
• Feed the 6-pole connector of the discharge control unit (A2 see circuit diagram) up along the
back of the angle plate into the slots "TA" to „N" of the terminal block X2 from above and screw
(press cable harness into the existing cable straps).
• Plug and snap in the discharge control unit (6) in the elongated holes above the charging
control unit.
• Plug the connecting lead of the potentiometer into the slot X21 of the room temperature
regulator.
• Screw the room temperature sensor (7/B2) with 2 screws (2.9 x 6.5) to the front edge of the
floor plate. Plug the connecting cable to slot X20 of the room temperature regulator.
• Lay the enclosed separate wires along the back of the angle plate and connect according to the
following table (to the terminals X1 and X2 from below).
Designation
wire (black)
wire (brown)
1
5
Wires may not touch the control panel circuit board and singly insulated wires for safety low
voltage!
Tie the wires to the switch in the existing cable harness (cable straps can be opened and
reclosed).
• Swing back the angle plate and screw tight.
• Stick the control panel label to the outside of the right side wall.
• Fix the side wall, front wall and air outlet and inlet grille back to the unit
(in the right order!).
The toothed washers must be inserted under the fastening screws (protective earth connec-
tion!)
The connecting lead from the control panel to the room temperature regulator must be laid and
secured in the same way as the existing leads to the control panel. They may not touch the inter-
mediate wall and the heating element connections.