of the window. Once the closure phase has been
completed, check that the window frame is
completely closed by checking the pressure on the
weather strips.
14.3. Assembly on transom window
Aside the drawing of specific application using
accessories provided. For different mountings,
please contact manufacturer.
Before starting, check that there are at least two
mechanical compass safety stops or other form
of stops connected to the frame, and ensure that
the stops can prevent any accidental fall of the window.
Your safety is at hand.
A. Pencil in an "X" over the centre line of the window
frame (Fig. 7).
B. Select the correct form of brackets (Fig. 8).
C. Attach the template to the window frame (fixed part)
and line axis up with the centre line "X" traced earlier
(Fig. 9). Warning: for window frames not on the
same plane, cut the part of the template coloured in
grey and fix this to the moveable part of the window
frame, taking care to keep it in the same position.
D. Bore holes in the window frame at the points
indicated on the template (Fig. 10).
E. Assemble the two brackets with the distancer (to
help position correctly. Once it has served its
purpose it can be removed). Mount the supports
onto the frame with the appropriate screws provided.
Check that everything is aligned both horizontally
and vertically.
F. Mount the bracket for outward opening windows onto
the moveable part of the frame in accordance with
the markings indicated on the template.
G. Complete assembly of the chain terminal with the
safety clip inserted onto the provided pin Ø4x32 in
median position (see fig. 11).
H. Mount the actuator onto the brackets by inserting the
two openings at each side onto the corresponding
pins on the brackets.
42
Inward application–transom window
Figure 6
Figure 7
Figure 8
Figure 9