4
OPERATION AND MAINTENANCE
Read item 3 USAGE CONDITIONS
4.1 ENGINE CONNECTION TO FLEXIBLE SHAFT
The engine (not supplied) is intended to connect the transmissions quickly and safety.
Connection procedure:
Connection possibilities
4.2 ASSEMBLY OF THE FLEXIBLE SHAFT TO THE PUMP SET.
The pump connection of the flexible shaft must be screwed to the shaft of the pump head.
en
Once screwed, The hose must be connected to the pump set using the nut. Tighten the nut firmly by
hand.
4.3 WATER PUMP OPERATION
Once the Flexible Shaft has been connected to the Power Unit, start the Engine. Whilst in the idle
speed position, slowly lower the Pump into the water and then gradually build up to maximum speed of
2800 rpm.
When stopping pumping, slow the engine back down to idle speed whilst the pump is still in the water.
Then slowly bring the pump out of the water and switch off the engine
Remove any dirt or dust from drive, pump head, flexible shaft and pressure hose after use.
4.4 INSPECTION
1.
2.
3.
4.
6
Type "D": raise the handle of the location pin, introduce the coupling up to the pin
1.
is in the slop and release the handle. Make sure that the flexible shaft is locked firmly in
place.
Type "H": Turn the ring on the engine coupling up to the stop and hold it, insert the
2.
flexible shaft in the housing right up to the stop and let go of the ring. Make sure that the
flexible shaft is locked firmly in place.
Length of transmission:................ Until 6 m:
Water pump:.............................Submersible type, 3" outlet.
Before starting the work, check the correct working of all handling and safety devices.
Before starting check that the water pump is in good use and it works correctly. Use the
means of safety and protection.
Do not work in closed rooms. The exhaust fumes may be toxic. Check the gas level. Check the
oil level, it must be in maximum level (See the instruction manual).
If defects are found in the safety devices or other defects which could reduce the safe handling
of the equipment, stop working and do the maintenance.
PUMP UNIT 3" + FLEXIBLE SHAFT 6m VOLGA
VOLGA IMMERSION PUMPS