Section 4 − Specifications; Serial Number And Rating Label Location; Unit Specifications; Duty Cycle And Overheating - Red-D-Arc Welderentals EXTREME 360 Mode D'emploi

Table des Matières

Publicité

4-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Unit Specifications

Input
Power
Rated Output
3-Phase
350 A at 34
VDC, 60%
Duty Cycle
1-Phase
300 A at 32
VDC, 60%
Duty Cycle*
*See Section 4-3 for Duty Cycle Rating.

4-3. Duty Cycle And Overheating

500
425
400
350
300
250
200
150
100
10
15
Overheating
OM-229 409 Page 12
SECTION 4 − SPECIFICATIONS
Amperage
Voltage
Range in
Range in CV Mode
CC Mode
10−38 V
5−425 A
20
25
30
40
50 60 70 80 90 100
% DUTY CYCLE
6 Minutes Welding
Minutes
RMS Amps Input at Rated Load Output,
Max.
60 Hz 3-Phase at NEMA Load Voltages
Open-
and Class I Rating
Circuit
208 V
230 V
Voltage
75 VDC
40.4
36.1
60.8
54.6
THREE PHASE
OPERATION
6 AWG POWER CORD
8 AWG POWER CORD
60% Duty Cycle
4 Minutes Resting
0
15
Reduce Duty Cycle
400 V
460 V
575 V
KVA
20.6
17.8
14.1
14.2
29.7
25.4
19.9
11.7
Duty Cycle is percentage of 10 minutes
that unit can weld at rated load without
overheating.
If unit overheats, output stops, a Help
message is displayed and cooling fan
runs. Wait fifteen minutes for unit to
cool. Reduce amperage or voltage, or
duty cycle before welding.
.
Single Phase Operation: The unit
is supplied with a 8 AWG power
cord. The rated output with 8
AWG is 300 amps, 32 volts at
40% duty cycle. To achieve 60%
duty cycle change cord to 6 AWG.
NOTICE − Exceeding duty cycle can
damage unit and void warranty.
SINGLE PHASE
OPERATION
A or V
OR
Ref. 216 568-A
KW
13.6
11.2

Publicité