Nova ACG8037 Mode D'emploi page 15

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

They are produced in versions for wall mounting, for mounting to columns of iron or other
smooth material, or on dedicated SUPPORT COLUMNS code ACG8039.
MOUNTING
Before placing the drilling template
(code CVA1940) make sure that the
contact surface is clean.
- Affix the plastic bases CPL1312 to the
pillars or columns about 40÷60 cm
from the ground and at a maximum
distance of 10 cm from the conveyance
or pressure area or immediately out of
range of any protruding edge.
- After adjustment attach the protective
casing CPL1311.
- Install the NOVA Wi-Fi receiver a
maximum distance of 20 m from
the MASTER Wi-Fi card in order to allow
correct radio function and in a shaded
area or in a position not exposed to
horizontal sunlight for correct infrared
signal operation.
- In every case it is advisable to place the
photocells at the same height and in line
with each other.
- For the correct positioning of the
photocells refer to the user installation
manual or to standard EN12453.
THE RECEIVER OF THE PHOTOCELLS MUST BE IN CLEAR VIEW OF THE MASTER Wi-Fi BOARD
NO OBSTACLES SUCH AS WALLS, PILLARS OR METAL CABINETS MUST BE PRESENT BETWEEN THE RECEIVER OF THE NOVA Wi-Fi PHOTOCELLS AND THE MASTER Wi-Fi BOARD.
If it is not possible to avoid that because the obstacles cannot be removed, please install an 868 MHz aerial (code ACG5451) on the MASTER Wi-Fi and position it so to guarantee a good quality
radio communication between the parts.
This solution also prevents the quick discharge of the batteries on the NOVA Wi-Fi.
NOVA Wi-Fi photocells may be installed very close together thanks to SYNCHRONIZATION.
SYNCHRONIZATION is guaranteed for up to 2 pairs of photocells with DIP 1 ON (1
2 ON (2
nd
pair).
CPL1311
st
pair) and DIP
TX PHOT 1
TX PHOT 2
RX PHOT 3
RX PHOT 4
BC08037R
BC08037T
Another 2 pairs of photocells may be installed, with transmission/reception inverted from that
of the 2 previous pairs.
DIPes must be set: DIP 3 ON (3
rd
pair) and DIP 4 ON (4
RX PHOT 1
RX PHOT 2
TX PHOT 3
TX PHOT 4
15
CPL1312
CVA1940
th
pair).
G