5.4
Electrical connection
INOPERABLE PRODUCT
•
Verify that the transparent hose of the pressure sensor is not closed or bent.
Failure to follow these instructions can result in equipment damage.
Verify that the the moisture-proof junction box is closed in such a way that
it is water-tight.
Verify that the moisture-proof junction box is closed in such a way that it
is not air-tight.
5.4.1
Connection diagram
Verify that the cables of the pressure sensor and of the control unit
have been routed into the moisture-proof junction box.
1. Connect the cables using the terminal strip.
2. Close the moisture-proof junction box.
Mounting
B
C
D
E
NOTICE
A
A. Cable from control unit
B. White (U+)
C. Green (signal)
B
D. Brown (U-)
C
E. Yellow/black (shield)
D
F. Terminal strip
E
G. Cable from pressure sensor
F
G
EN
13
DIT 10