Electrical Connections - Joannes LADY 30 S Manuel D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22

ELECTRICAL CONNECTIONS

The circulators, burner and any room thermostat should be connected following the indications in the attached
wiring diagrams. We advise you to place a bipolar switch with contacts having at least a 3 mm aperture
between the supply mains and the appliance, equipped with max. 5 A fuses. Connect the boiler to a 230 V -
50 Hz phase/neutral supply mains.
We recommend you connect the appliance to a good earth connection.
Lamborghini declines any responsibility for damage to persons or property occurring because the appliance
has not been connected to a good earth connection.
L N
IG
M
VD
USCITA
230 VAC
fig. 6 a
Magneto-thermal switch for electrical panel power supply
IG
sectioning (by the installer)
SC
Boiler sensor
TA
Room thermostat
FL
Hot water micro flow switch
F1
6.3 A delayed-action fuse
Heating circuit circulator
PI
VD Diverting valve for "micro-storage" water circuit (=OFF)
and heating system (=ON)
TS
Safety water thermostat 100
M2 Lumberg connector for boiler sensor and micro flow
switch connection
LADY S
PI
5
4
3
M6
F1
N
M3
L
N
LC
SC
JP2
- JP2=ON
- JP1=OFF
1
O
C (-6°C)
TS
1
2
C
CN1
1
2
3
4
5
6
7
M5
2
1
M7
TA
M2
JP2
JP1
J1
FL
JP1
M3 Removable terminal block for electrical panel power supply
M5 Stelvio connector for system pump connection
M6 Terminal for earth connection
M7 Removable terminal block for room thermostat
SBR Wieland thorn 7 poles for burner
1
Boiler mode selection
0 - winter/summer mode selector
2
3
Heating potentiometer
4
Burner lock-out
5
Faults
SBR
Burner lead
2
2
POT3
B&P CP 11.01
BLOCCO
ANOMALIE
ON
4
18
3
POT2
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lady 30 r

Table des Matières