FEATURES
This control unit is designed for the automation of:
- two-leaf gates with or without limit switches
- single leaf gates with or without limit switches
- double leaf sliding gates with limit switches
- single leaf sliding gates with limit switches
The control unit is equipped with:
- encoder and/or current sensitivity motor control
- programmable motor deceleration
- soft start
- photocell operation check (Photo Test)
- self-diagnostics of motor drives (MOSFET)
- connectors for OC receivers and/or BOARD receivers

TECHNICAL DATA

Electrical parameters
Power supply
Frequency
Absorption on stand-by (230V)
Maximum absorption (230V)
Max. motor output 24V
operating temperature
Box dimensions (L x H x D)
38
U.M.
Vac
Hz
mA
A
VA
°C
mm
E224
230 ±10%
50/60
18 / 25 min / max
2
360 (2X180)
-20 +60
220x280x120