Change Engine Oil; Air Filter; Service Spark Plug - Generac PRO 6712 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Figure 4-11. Safe Operating Range
5. Add
recommended
necessary.
6. Replace oil fill cap and hand-tighten.
NOTE: Some units have more than one oil fill
location. It is only necessary to use one oil fill
point.

Change Engine Oil

When using power washer under extreme,
dirty, dusty conditions, or in extremely hot
weather, change oil more frequently.
NOTE: Don't pollute. Conserve resources.
Return used oil to collection centers.
Change oil while engine is still warm from
running, as follows:
1. Place power washer on a level surface.
2. Disconnect the spark plug wire from the
spark plug and place the wire where it
cannot contact spark plug.
3. Clean area around oil fill, and oil drain
plug.
4. Remove oil fill cap.
5. See
Figure
4-12. Remove oil drain plug (A)
and drain oil completely into a suitable
container.
6. Install oil drain plug and tighten securely.
7. See
Figure
4-11. Slowly pour oil into oil fill
opening until oil level is between L and H
marks on dipstick. DO NOT overfill.
8. Install oil fill cap, and finger tighten.
9. Wipe up any spilled oil.
10. Properly dispose of oil in accordance with
all applicable regulations.
Figure 4-12.Oil Drain Plug
Owner's Manual for Power Washer
000116
engine
oil
as
000276
Maintenance and Troubleshooting

Air Filter

Engine will not run properly and may be
damaged if run with a dirty air cleaner. Service
air cleaner more frequently in dirty or dusty
conditions.
To service air cleaner:
1. See
Figure
4-13. Remove air cleaner cover
(A).
2. Remove filter element(s) (B).
3. Inspect filter element(s) and replace if
damaged. To order replacements, contact
Generac Customer Service at 1-888-
GENERAC (888-436-3722) for the name
of your nearest IASD.
4. Clean foam filter element in warm soapy
water. Rinse, and allow to dry thoroughly.
Dip in clean engine oil and squeeze out
excess oil.
5. Tap paper filter element several times on
hard surface to remove dirt. Compressed
air (not exceeding 30 psi (207 kPa) can
also be used to blow through filter element
from the inside.
6. Use a clean, damp cloth to wipe dirt from
inside air cleaner cover.
7. Put cleaned or new filter element(s) in
place. Verify gasket is in place (if
equipped).
8. Install air cleaner cover. Tighten air
cleaner screws or fasteners securely.
B
Figure 4-13.Air Filter Assembly

Service Spark Plug

To service spark plug:
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. See
Figure
4-14. Inspect electrode gap
with wire feeler gauge and replace spark
plug if gap (A) is not within specification
listed on Product Specifications Sheet.
A
000277
15

Publicité