Nivotemp NT M-XP
8 Menu Sequence Overview
Main menu
Submenu 1
Configuration
o__i
Shortcut
+
Equipment configuration
or 60s no action:
Exit main/submenu
____
Display
____
Measurement display
____
out1
____
Level
oil
Out 1
Liquid level main menu
Settings menu OUT1
Out x
out_
____
Settings menu OUTx
____
Analog Out1
An1
Settings menu Analog 1
E
Exit
Exit menu level
Temperature
tEMP
Out 1
out_
Temperature Menu
Settings menu OUT 1
out_
Out X
Settings menu OUT X
Analog Out2
An2
Settings menu Analog 2
Exit
E
Exit menu level
b. E F
rES
Basic EF
Reset
Basic Adv. Functions
Factory setting
errh
Set error handling
Error handling
Set Unit Level
o. u ni
Liquid level unit
Set Unit Temp
t. u ni
Temperature unit
Set Upper
o. H i
Assign 100 %
Set Lower
o. L o
Assign 0 %
reassign O1
r. o u1
Assignment Out 1
reassign O2
r. o u 2
Set Out 2
reassign Ox
r. o u_
Set Out x
di5
Display Rate
Display rate
Loc
Lock Device
Keylock
Exit
E
Exit menu level
Diagnostic
diA
Journal Out
J. o ut
Diagnostics menu
Logs output
Max/Min Level
o. M M
Max/Min memory
Max/Min Temp
t. M M
Max/Min memory
Set Journal Out
SJ. o u
Output monitoring
Delay MM
Do. M M
Min/Max Delay
Delay MM
dt. M M
Min/Max Delay
E
Exit
Exit menu level
E
Exit
Exit menu level
BX100023 ◦ 06/2021
Submenu 2
Submenu 3
____
SP1
____
FH1
F1. H i
Switching point 1
rP1
____
FL1
F1. L o
____
Switch-back point 1
EF1
____
dS1
____
EF 1
Delay SP 1
Advanced Functions
Delay OUT1 On
____
Delay RP 1
dr1
Delay OUT1 Off
____
Set Out 1
ou1
Definition OUT1
____
Check Out 1
C. o u1
Functional test OUT1
____
LED Out 1
LEd1
Function status LED1
____
Exit
E
Exit menu level
____
Exit
E
Exit menu level
See menu structure Out1
Not applicable for version with
analogue output
____
Analog Max1
A1. H i
Set maximum value
____
Analog Min1
A1. L o
Set minimum value
Set A.Out1
____
A. o u1
Output function
C. A n1
____
Check An1
Functional test Analog 1
E
____
Exit
Exit menu level
See menu structure Out1
See menu structure Out1
Not applicable for version with analogue output
See menu structure Analog Out1
Settings and Display Menu
Switch
____
____
Switches the measurement display level / temperature
Switch view
____
____
Selection menu
SP1
Setting the switching point /
< o. L o - o. H i >
FI. H i
Sets a value for frequency 100 Hz (only OUT1 and OUT2)
____
Selection menu
____
rP1
Set switch-back point /
FL1 Define minimum window limit
FI. L o
Sets a value for frequency 1 Hz (only OUT1 and OUT2)
< o. L o - o. H i >
____
Selection menu
___
Amount of time the signal must be present for output OUT1 to trigger.
0 - 100
Setting range: 0...100 seconds (for frequency output without function)
____
Selection menu
___
Amount of time the signal must be present for output OUT1 to switch back.
0 - 100
Setting range: 0...100 seconds (for frequency output without function)
Definition of switching characteristics for output 1:
____
Selection menu
___
Hno Hnc Hysteresis function NO contact or NC contact
Hno - FM
Fno Fnc Window function NO contact or NC contact /
n. o P
Normal switching output operation
____
Selection menu
____
oFF
F1
Switching output Off /
n. o p - on
on
Switching output On /
F100
____
Selection menu
L=__
LED = output: follows switching output
L= o
L= o - L=-o
L=-o
LED = -output: inverted to switching output
____
Selection menu
____
Sets the maximum analogue output signal to a defined value.
(Note: Max. – Min >= 10 % of the measuring range)
0°C - 100°C
____
Selection menu
____
Sets the maximum analogue output signal to a defined value.
0°C - 100°C
(Note: Max. – Min >= 10 % of the measuring range)
____
Selection menu
_ _
Selecting the analogue output function:
i I
4...20 mA
u 1
2...10 V
i 1 - u 3
____
Selection menu
____
Analogue output normal mode /
n. o P
n. o P - Lo
HALF
Output mean analogue value /
Alternate menu for version with analogue output
Not applicable when ordered with 2 or more switching outputs
Alternate menu for version with analogue output
Not used when ordered with 4 switching outputs
____
Confirm
___
Resets the device to factory settings
no - YES
Selection menu
____
Disable/enable normal error handling and analysis
___
no - Yes
____
Selection menu
Selecting the unit of length displayed:
___
Lit [litre], CAL [Gallon],
non /
non1 non2
-l- - non2
____
Selection menu
°_
Selecting the temperature unit displayed:
°C [Celsius],
°F [Fahrenheit]
°C - °F
____
Selection menu
____
Assigns the maximum liquid level of a defined value.
(Example: Maximum liquid level at 100 cm)
-999 - 9999
____
Selection menu
____
Assigns the minimum liquid level of a defined value.
-999 - 9999
(Example: Minimum liquid level at 10 cm)
____
Selection menu
____
Assigns switching output Out1 to liquid level measurement,
oil - tEMP
temperature measurement or as error signal
Selection menu
Set switching output Out2 to liquid level/temperature
____
measurement or as error signal.
oil - tEMP
Selection menu
____
____
Assigns the switching output OutX to liquid level measurement or temperature
measurement
oil - tEMP
Selection menu
____
____
Selecting the display refresh rate:
FASt - off
FASt [fast], Medi [medium], SLo [slow],
Selection menu
____
___
Activating the keylock by entering a numerical code > 0 Master code 287
0 - 999
____
Selection menu
____
Displays the last 6 alarms + delete function.
Jor I - ---
Display:
JorX
X – amount of time passed in hours/days; scroll through journal with ▲▼
Selection menu
____
____
Displays the limits + delete function.
____ - ---
Display: Value – amount of time passed in hours/days; scroll through journal with ▲▼
Selection menu
____
____
Displays the limits + delete function.
Display: Value – amount of time passed in hours/days; scroll through journal with ▲▼
____ - ---
Selection menu
____
out_
Selecting the alarm output to be logged
Out1 - Out_
Selection menu
____
___
Amount of time the signal must be present before saving the maximum / minimum
value. Setting range: 0...100 seconds
0 - 100
Selection menu
____
___
Amount of time the signal must be present before saving the maximum / minimum
0 - 100
value. Setting range: 0...100 seconds
FH1 Define maximum window limit
FM
Frequency output 1-100 Hz
Simulation 1 Hz
Simulation 100 Hz
u 2 0...10 V
u 3 0...5 V
Hi Output maximum analogue value
Lo Minimum analogue value output
[Percent],
cn
[cm], in [inch],
-1-
/
[no unit (4-digit display)]
oFF [Display off]
Bühler Technologies GmbH
11