Installing Lp Gas Tank; Operating Instructions - Endless Summer GAD1390SP Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8

Installing LP Gas Tank

To operate, you will need one precision-filled standard grill LP gas
tank with external valve threads .
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
outdoor fireplace.
Inserting LP Gas Tank
W WARNING: Make sure LP gas tank valve is closed.
1 .
Slide-out LP gas tank tray .
2 .
Place precision-filled LP gas tank upright into hole in outdoor fireplace base so the tank
valve is facing the gas line connection .
Connecting LP Gas Tank
1 .
Before connecting, be sure there is no debris caught in the
head of the LP gas tank, head of the regulator valve or in the
head of the burner or burner ports .
2 .
Connect regulator/hose assembly to tank by turning knob
clockwise until it stops .
Secure LP Gas Tank
1 .
Secure tank by sliding tank retainer chain around the LP gas tank .
2 .
Gently push LP gas tank tray into base .
3 .
Insert peg into LP gas tank tray .
Note: Peg must be inserted into LP gas tank when tank is in LP gas tank tray .
Disconnecting LP Gas Tank
1 .
Lift peg from LP gas tray .
2 .
Gently pull LG gas tray from base
3 .
Turn the LP gas valve to "CLOSED ."
4 .
Disconnect regulator/hose assembly from LP gas tank by
turning knob counterclockwise until it is loose .
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this outdoor fireplace.
5 .
Place the protective cap cover on the LP tank and store the tank outdoors in a well
ventilated area out of direct sunlight .
6 .
Gently push LP gas tank tray into base .
7 .
Insert peg into LP gas tank tray and base .
®

Operating Instructions

Checking for Leaks
W WARNING: Before using this outdoor
20 lb
fireplace, make sure you have
9 Kg
read, understand and are following
all information provided in the
"Important Safeguards" section
12.2 in. / 31 cm
on page 2. Failure to follow those
instructions can cause death, serious
injury or property damage.
Burner Connections
1 .
Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank .
2 .
Visually check the connection between the
burner/venturi tube and orifice .
3 .
Make sure the burner/venturi tube fits over the
orifice .
W WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury or damage to
property.
4 .
Please refer to diagram for proper installation
(Figures 1 and 2) .
5 .
If the burner/venturi tube does not rest flush
to the orifice, as shown, please contact
1 .800 .762 .1142 for assistance .
Tank/Gas Line Connection
1 .
Make 2-3 oz . of leak detection solution by
mixing one part liquid dishwashing soap with
three parts water .
2 .
Make sure control knobs are in the " OFF"
position (Figure 3) .
3 .
Connect LP gas tank per "Installing LP Gas
Tank" section .
4 .
Turn LP gas tank valve to "OPEN ."
5 .
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1 and 2) .
a . If any bubbles appear, turn LP gas tank valve
b . If you continue to see bubbles after
c . If no bubbles appear after one minute, turn
Lighting
W WARNING: NEVER light the burner with the cover on the outdoor
fireplace.
W WARNING: NEVER light the burner with the table insert on the outdoor
fireplace.
W CAUTION: Keep outdoor gas appliance area clear and free from
combustible materials, gasoline and other flammable vapors and
liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
1 .
Make sure all labels, packaging and protective films have been removed from the outdoor
fireplace .
2 .
Check for obstructions of airflow to the burner . Spiders, insects and webs can clog the
burner/venturi tube . A clogged burner tube can lead to a fire .
3 .
Control knob must be in the " OFF" position (Figure 3) .
4 .
Clear small area of glass rocks away from the igniter cover (Figure 4) .
5 .
Connect LP gas tank per "Installing LP Gas Tank" section .
6 .
Turn LP gas tank valve to "OPEN ."
7 .
Push and turn control knob to
8 .
Continue to hold the control knob in, press the (electronic igniter) and hold for up to
5 seconds to light the pilot .
9 .
Continue to hold the control knob in for 20 seconds to heat thermocouple .
10 . After 20 seconds, release and turn control knob counterclockwise to adjust flame to
desired height .
11 . If ignition does not occur in 5 seconds, turn burner control knob to " OFF," wait
5 minutes, fan with a newspaper or magazine, and repeat lighting procedure .
LP Gas Outdoor Fireplace
Model No. GAD1390SP
to "CLOSED," reconnect and re-test .
several attempts, turn LP gas tank valve to
"CLOSED" and disconnect LP gas tank, per
"Disconnecting LP Gas Tank" section . Contact
1 .800 .762 .1142 for assistance .
LP gas tank valve to "CLOSED," wipe away
solution and proceed .
(LOW) .
Figure 1
LP Gas
Connection
LP Gas Valve
with Orifice
Figure 2
X
X
X
X
X
Figure 3
OFF / ARRÊT
Figure 4

Publicité

Chapitres

Table des Matières
loading

Table des Matières