Protein Skimmer SCC 1660/SCC 2061
The Deltec SCC 1660 internal skimmer are very compact, highly efficient and
operate
operate in external filtersumps (diagram a)
practically 'noiseless'. He was designed to
The Pump
The internal skimmer SCC 1660 is powered by an 24 V DC pump (DCC 1100). This pump
includes a "soft start", this means the rotor will be slowly accelerated to its set at the controller
power stage. Through this slow acceleration is starting the Pump, even under difficult conditions,
guaranteed. The choice of the power stage by pressing the + and - buttons is carried out at the 8-
stage controller.
By pressing the "Feed" button the pump stopped for 10 minutes. After this, the pump continues to
operate at the previously set stage.
The transformer as well as the controller have to be placed in a dry and ventilated place to prevent
any possible damage through moisture or water.
Damages caused this way are except from warranty.
Installation
For best performance the water level in the filter sump (diagram a) should be between 160
and 250 mm. A prerequisite for continuous efficient performance is a constant water level in
which the skimmer operates. Ideally, a water level top up system should be used such as
the Deltec Aquastat 1001 or better still a separate skimmer compartment in the sump
(diagram b). The water level in the skimmer compartment should be higher than in the rest
of the sump. But within the levels recommended for the skimmer model.
This compartment can be supplied with water from a bypass of the aquarium overflow.
-10-