19. CONNEXIONS
19.1 XR570C
13 14 15
16
17 18
Max
8(3)A
8(3)A
8(3)A
10A
1
2
3
4
5
N.C.
Comp
Def.
Fan
Line
20. VALEURS DEFAUT
20.1 FUNCTION MENU
Label Name
Lot
Low temperature alarm
Hit
High temperature alarm
PASS Security code
20.2 PARAMETER LIST
Label Name
Set
Set point
Hy
Differential
LS
Minimum set point
US
Maximum set point
OdS
Outputs activation delay at start up
AC
Anti-short cycle delay
COn
Compressor ON time with faulty probe
COF
Compressor OFF time with faulty probe
CF
Temperature measurement unit
rES
Resolution (integer/decimal point)
Lod
Local display
tdF
Defrost type
EdF
Defrost mode
SdF
Set point for SMART DEFROST
dtE
Defrost
termination
temperature
(1°Evaporator)
IdF
Interval between defrost cycles
MdF
(Maximum) length for 1° defrost
dFd
Displaying during defrost
dAd
MAX display delay after defrost
dSd
Defrost delay after calling
Fdt
Draining time
dPO
First defrost after start up
FnC
Fans operating mode
Fnd
Fans delay after defrost
FSt
Fans stop temperature
AFH
Temperature alarm and fan differential
ALd
Temperature alarm delay
dAO
Delay of temperature alarm at start up
EdA
Alarm delay at the end of defrost
dAE
Temperat. alarm enabled during defrost
dOA
Open door alarm delay
tBA
Alarm relay silencing
nPS
Pressure switch activation number
ALP
Alarm probe selection
Ot
Thermostat probe calibration
OE
Evaporator probe calibration
O3
Auxiliary probe calibration
P2P
Evaporator probe presence
P3P
Auxiliary probe presence
HES
Temperature increase during the Energy
Saving cycle
Odc
Open door control
i1P
Door switch polarity
i2P
Configurable digital input polarity
XR775C_HACCP.doc
19 20 21
22 23
8(3)A/250Vac
6
7
8
9
10
N.C. Line
Light
Range
Default
-40°C÷Hit
Lot ÷110°C
0÷999
Range
Default
LS÷US
0,1÷25,5 °C / 1÷45°F
-50,0°C÷SET / -58°F÷SET
-30.0
SET ÷ 110°C / SET ÷ 230°F
20.0
0÷255 min.
0÷30 min.
0÷255 min.
0÷255 min.
°C ÷ °F
in ÷ de
P1 ÷ 1r2
rE, rT, in
rtc, In, Sd
-30 ÷ +30°C / -22÷+86°F
-50,0÷110°C /-58÷230°F
1÷120h
0÷255 min.
rt, it, SEt, dEF, dEG
0÷255 min.
0÷255 min
0÷60 min.
n ÷ y
C-n, C-y, O-n, O-y
0÷255 min.
-50,0÷110°C / -58÷230°F
0,1÷25,5 °C/ 1÷45°F
0÷255 min.
0 ÷ 23h 50 min.
0÷255 min.
y ÷ n
0÷254 min.,nu
y ÷ n
0÷15
P1, P2, P3
-12,0÷12,0°C / -21÷21°F
-12,0÷12,0°C / -21÷21°F
-12,0÷12,0°C / -21÷21°F
n ÷ y
n ÷ y
-30÷30°C / -54÷54°F
no, Fan, CPr, F_C
FAn
CL÷OP
CL÷OP
Operating Instructions
Label Name
i2F
Digital input configuration
dId
Digital input alarm delay
oA3
IV relay configuration
LdE
Light switching off after door closing
Hur
Current hour
Min
Current minute
UdA
Current day of the week
dAY
Current day
MOn
Month
YEA
Year
Hd1
First weekly holiday
Hd2
Second weekly holiday
Hd3
Third weekly holiday
ILE
Energy Saving cycle start during workdays
dLE
Energy
workdays
ISE
Energy Saving cycle start on holidays
dSE
Energy Saving cycle length on holidays
HES
Temperature increase during the Energy
Saving cycle
Ld1
1
workdays defrost start
st
Ld2
2
workdays defrost start
nd
Ld3
3
workdays defrost start
rd
Ld4
4
workdays defrost start
th
Ld5
5
workdays defrost start
th
Ld6
6
workdays defrost start
th
Ld7
7
workdays defrost start
th
Ld8
8
workdays defrost start
th
Sd1
1
holiday defrost start
st
Sd2
2
holiday defrost start
nd
Sd3
3
holiday defrost start
rd
Level
Sd4
4
holiday defrost start
th
-20
MENU
Sd5
5
holiday defrost start
th
MENU
20
Sd6
6
holiday defrost start
th
MENU
000
Sd7
7
holiday defrost start
th
Sd8
8
holiday defrost start
th
Adr
Serial address
Level
dP1
Room probe readout
-5
Pr1
dP2
Evaporator probe readout
2.0
Pr1
dP3
Third probe readout
Pr2
rEL
Software release
Pr2
Ptb
Map code
0
Pr2
Pr2
Access parameter list
1
Pr1
15
Pr2
30
Pr2
°C
Pr2
dE
Pr1
P1
Pr2
rE
Pr2
rtc
Pr2
0
Pr2
8.0
Pr1
6
Pr2
30
Pr2
it
Pr2
30
Pr2
0
Pr2
0
Pr2
n
Pr2
O-n
Pr2
10
Pr2
2,0
Pr2
2.0
Pr2
15
Pr2
1,3
Pr2
30
Pr2
n
Pr2
15
Pr2
y
Pr2
0
Pr2
P1
Pr2
0.0
Pr2
0.0
Pr2
0.0
Pr2
FRIGRO NV
Y
Pr2
DRIESLAAN 10
n
Pr2
tel. +32 - 56419593 - fax +32 - 56403155
0
Pr2
E-mail: INFO@FRIGRO.BE
Pr2
cL
Pr2
cL
Pr2
XR775C
EAL, bAL, PAL,
dFr, AUS, ES, OnF
ALr – Fan – Lig - AUS –onF
Sun÷ SAt – nu
Sun÷ SAt – nu
Sun÷ SAt – nu
0 ÷ 23h 50 min.
Saving
cycle
length
during
0 ÷ 24h 00 min.
0 ÷ 23h 50 min.
0 ÷ 24h 00 min.
-30÷30°C / -54÷54°F
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
0 ÷ 23h 50 min. - nu
8560 MOORSELE
PRELIMINARY
Range
Default
Level
EAL
Pr2
0÷255 min.
0
Pr2
Lig
Pr2
0÷255 min.
0
Pr2
0 ÷ 23
-
rtc
0 ÷ 59
-
rtc
Sun) ÷ SAt
-
rtc
1 ÷ 31
-
rtc
1 ÷ 12
-
rtc
0 ÷ 99
-
rtc
nu
rtc
nu
rtc
nu
rtc
0.0
Pr2
0.0
Pr2
0.0
Pr2
0.0
Pr2
0
Pr2
6.0
Pr2
13.0
Pr2
21.0
Pr2
nu
Pr2
nu
Pr2
nu
Pr2
nu
Pr2
nu
Pr2
6.0
Pr2
13.0
Pr2
21.0
Pr2
nu
Pr2
nu
Pr2
nu
Pr2
nu
Pr2
nu
Pr2
0÷247
1
Pr1
- - -
- - -
Pr1
- - -
- - -
Pr1
- - -
- - -
Pr1
- - -
- - -
Pr2
- - -
- - -
Pr2
- - -
- - -
Pr2
6/6